WSS INVERTER MZ2000 series Compact Vector Control

– Senseless flux vector control (VC), V/F (Voltage/Frequency) control
– Overload capacity is 150% (100%) of the rated current, 3s for 180% of the rated current
– There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis
– Suppot PM motor (MZ2000 T sereies)

Power range

MZ2200   : 220V / 0.25 ~ 3.7kW
MZ2400   : 380V / 0.75 ~ 450kW

Technical specification
Item
specification
Standard Functions Control mode V/F (Voltage/Frequency) control                                                    Senseless flux vector control (VC)
Maximum frequency Vector control: 0 – 300Hz; V/F control: 0 – 3200Hz
Carrier frequency 1.0 – 16.0kHz; The carrier frequency is automatically adjusted based on the load features.
Input frequency solution Digital setting: 0.01Hz                                                                        Analog setting: 0.025% of maximum frequency
Startup torque G type: 0.5Hz / 150% (VC)                                                                 P type: 0.5Hz / 100% (VC)
Speed range / stability accuracy 1:100 (VC) / ± 0.2% (VC)
Torque control accuracy ± 0.2%
Overload capacity G type : 60s for 150% of the rated current, 3s for 180% of the rated current.
Torque boost Auto boost                                                                         Customized boost 0.1% – 30.0%
V/F curve Line V/F curve                                                                                   Multi-point V/F curve                                                                         N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square
V/F separation Two types: complete separation; half separation
Ramp mode Sraight-line ramp; S- curve ramp                                                      Four groups of acceleration/deceleration time with the range of 0.0 – 6500.0s
Standard Functions DC braking DC braking frequency: 0.00Hz to maximum frequency               Braking time: 0.0 – 100.0s; Braking action current  value: 0.0% – 100.0%
JOG control JOG frequency range: 0.00 – 50.00Hz                                             JOG acceleration/deceleration time: 0.0 – 6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of termial states.
Onboard PID It realized process-controlled closed loop control system easily.
Auto voltage regulation (AVR) It can keep constant output  voltage automatically when the mains voltage changes.
Overvoltage/ Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage / over current
Torque limit and control It can limit the torque automatically and prevent frequent over current tripping during the running process.
Power dip ride through The load feedback energy compensates the voltage reduction so that the  AC drive can continue to run for a short time.
Rapid current limit It helps to avoid frequent over current faults of the AC drive.
High performance Control of asynchronous motoris implemented through the high-performance current  vector control technology.
Timing control Time range: 0.0 – 6500.0 minutes
Communication methods RS485 (MODBUS-RTU)
Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection.
Input and Output Input terminal 6 digital input terminals, one of which supports up to 100kHz high-speedpulse input.                                                                      2 analog input terminals, one of which only supports 0 – 10V voltage input and the other supports 0 – 10V voltage input or 4 – 20mAcurrent input.
Frequency source Digital setting, analog voltage setting, analog current setting, pulse setting and  serial communication port setting.
Auxiliary frequency source There are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis.
Running command source Operation panel / Control terminals / Serial communication port. You can perform switchover between these sources in various ways.
Output terminal 1 digital output terminal; 1 relay output terminal                           1 analog output terminal: that support 0 – 20mA current output or 0 – 10V voltage output.
Keyboard LED display It displays the parameters.
Key locking and function selection It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function.