Product category

Loading...

WSS MZ3000 series AC VFD

WSS MZ3000 Series – Special for air compressor

-The inverter uses metal structure, support both floor & wall mounting
– It can embed the appliance of air compressor directly and do not need the electric control cabinet
– Intergrated the inverter, HMI, compressor controller, PTC/PT100 input, phase detector, fan control, fuse and transformer
– The integrative MZ3000 inverter can supports both synchronous and asynchronous motor

Features and advantage
• Small size, each of installation
• Stable operation, decreasing the times of repair
• Avoiding the loss on unnecessary power
• Controlling system of colorful touching screen
• A wider range of working frequency and low noise
• Control of the high-efficient permanent-magnet motor, save the energy

Technical specification

Item
specification
Basic control functions Control mode Open loop and vector control                                                     V / F control
Maximum frequency Open loop and vector control: 0~500 Hz                                   V / F control
Carrier frequency Digital setting: 0.01Hz, the carrier frequency is automatically adjusted based on the load features
Input frequency esolution Digital setting: 0.01Hz                                                                Analog setting: maximum frequency is x 0.025%
Startup torque 0.5 Hz/150%
Speed range 1:100
Speed stability accuracy ± 0.2% (SFVC)
Torque control accuracy ± 10%
Overload capacity 60s for 150% of the rated current, 3s for 180% of the rated current
Torque boost Fixed boost; Customized boost 0.1%-30.0%
V/F curve Straight-line V/F curve                                                          Multi-point V/F curve                                                                N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)
V/F separation two types: complete separation; half separation
Ramp mode Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0 – 6500.0s
Communication methods RS485
JOG control JOG frequency range: 0.00 – 50.00Hz                                JOG acceleration/deceleration time: 0.0 – 6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of X terminal states
Built-in PID It realized process-controlled closed loop control system easily.
Auto voltage regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Frequency source Digital setting
Input and output interfaces Analog Input 2 pressure sensor: 4~20mA input;                                            2 temperature sensor: PT100
Digital Input 5 digital input; 1 PTC circuit protection (compatible with normal digital inputs)
Digital Output 2 normally open relay output (built 220VAC voltage)
LED diode display Standard 3 LED display
Protection Motor overhead protection (PTC), the power-to-ground short-circuit protection, inverter’s protection in over-current, overload, over voltage, under voltage, over temperature, output phase, communication fault, fault current detection, EEPROM write failure and so on
Fan Drive 15-55kW master drive: 1.5kW                                                    75-160kW master drive: 2.2kW