Power range
MODEL : MZ8400
220V: 0.75 ~ 3.7kW
380V: 0.75 ~ 630kW
Description
Technical specification
Item |
specification |
||
Based Functions | Control mode | V/F control; Senseless flux vector control (SFVC); Closed-loop vector control (CLVC) | |
Maximum frequency | Vector control: 0 – 320Hz; V/F control: 0 – 3200Hz | ||
Carrier frequency | 1.0 – 16.0kHz; The carrier frequency is automatically adjusted based on the load features. | ||
Input frequency esolution | Digital setting: 0.01Hz / Analog setting: 0.025% of maximum frequency | ||
Startup torque | G type: 0.5Hz / 150% (SFVC); 0 Hz / 180% (CLVC); P type: 0.5 Hz / 100% | ||
Speed range | 1 : 100 (SFVC) / 1 : 1000 (CLVC) | ||
Speed stability accuracy | ± 0.5% (SFVC) / ± 0.02% (CLVC) | ||
Torque control accuracy | ± 5% (CLVC) | ||
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type : 60s for 120% of the rated current, 3s for 150% of the rated current. | ||
Torque boost | Auto boost / Customized boost 0.1% – 30.0% | ||
V/F curve | Straight-line V/F curve; Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) | ||
V/F separation | two types: complete separation; half separation | ||
Ramp mode | Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0 – 6500.0s | ||
DC braking | DC braking frequency: 0.00Hz to maximum frequency Braking time: 0.0 – 100.0s; Braking action current value : 0.0% – 100.0% | ||
JOG control | JOG frequency range: 0.00 – 50.00Hz; JOG acceleration/deceleration time: 0.0 – 6500.0s | ||
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of X terminal states | ||
Onboard PID | It realized process-controlled closed loop control system easily. | ||
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage changes. | ||
Overvoltage / Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage / overcurrent. | ||
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode. | ||
Individualized Functions | Support for multiple PG card | Supporting for rotating transformer PG card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card | |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continute to run for a short time. | ||
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. | ||
High performance | Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology. | ||
Timing control | Time range: 0.0 – 6500.0 minutes | ||
Communication methods | MODBUS-RTU, PROFICUS-DP (optional), CANlink (optional), CAN (optional) | ||
Protection mode | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection. | ||
Input and output | Input terminal | 8 digital input terminals, one of which supports up to 100kHz high-speed pulse input. 2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. | |
Frequency source | Digital setting, analog voltage setting, analog current setting, pules setting and serial communication port setting. | ||
Auxiliary frequency source | There are ten auxiliary frequency source. It can implement fine tuning of auxiliary frequency and frequency synthesis | ||
Running command source | Operation panel / Control terminals / Serial communication port. You can perform switchover between these source in various ways. | ||
Output terminal | 1 high-speed pulse output termainal (open-collector) that supports 0-100 kHz square wave signal output. 1 digital output terminal :that supports 0-20 mA current output or 0-10 V voltage output. | ||
operation on the operation panel | LED display | It displays the parameters. | |
Key locking and function selection | It can look the keys partially or completely and defind the function range of some keys so as to prevent mis-function | ||
Optional parts | Rotating transformer PG card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card |