WSS MZ8000 series AC VFD

WSS MZ8000 series – Close Loop Vector Control

– Control Method: V/F Control; space vector control (SVC), closed loop vector control
– Modbus; Profbus; Can; Wifi / GRRS; Tension control
– Multi-speed and simple PLC setting; PID setting etc, can achieve the set combinations and mode swithing
– Supports MODBUS via RS485
– Maintenance-free

Power range

MODEL : MZ8400
220V: 0.75 ~ 3.7kW
380V: 0.75 ~ 630kW

 

Technical specification
Item
specification
Based Functions Control mode V/F control; Senseless flux vector control (SFVC); Closed-loop vector control (CLVC)
Maximum frequency Vector control: 0 – 320Hz; V/F control: 0 – 3200Hz
Carrier frequency 1.0 – 16.0kHz; The carrier frequency is automatically adjusted based on the load features.
Input frequency esolution Digital setting: 0.01Hz / Analog setting: 0.025% of maximum frequency
Startup torque G type: 0.5Hz / 150% (SFVC); 0 Hz / 180% (CLVC); P type: 0.5 Hz / 100%
Speed range 1 : 100 (SFVC) / 1 : 1000 (CLVC)
Speed stability accuracy ± 0.5% (SFVC) / ± 0.02% (CLVC)
Torque control accuracy ± 5% (CLVC)
Overload capacity G type: 60s for 150% of the rated current, 3s for 180% of the rated current.                                                                                         P type : 60s for 120% of the rated current, 3s for 150% of the rated current.
Torque boost Auto boost / Customized boost 0.1% – 30.0%
V/F curve Straight-line V/F    curve; Multi-point V/F curve                            N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)
V/F separation two types: complete separation; half separation
Ramp mode Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0 – 6500.0s
DC braking DC braking frequency: 0.00Hz to maximum frequency            Braking time: 0.0 – 100.0s; Braking action current  value : 0.0% – 100.0%
JOG control JOG frequency range: 0.00 – 50.00Hz; JOG acceleration/deceleration time: 0.0 – 6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of X terminal states
Onboard PID It realized process-controlled closed loop control system easily.
Auto voltage regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Overvoltage / Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage / overcurrent.
Torque limit and control It can limit the torque automatically and prevent frequent over current tripping during the running process. Torque control can be implemented in the CLVC mode.
Individualized Functions Support for multiple PG card Supporting for rotating transformer PG card, differential input PG card, UVW  differential input PG card, resolver PG card and OC input PG card
Power dip ride through The load feedback energy compensates the voltage reduction so that the AC drive can continute to run for a short time.
Rapid current limit It helps to avoid frequent over current faults of the AC drive.
High performance Control of asynchronous motor and synchronous motor are implemented through the high-performance current  vector control technology.
Timing control Time range: 0.0 – 6500.0 minutes
Communication methods MODBUS-RTU, PROFICUS-DP (optional), CANlink (optional), CAN (optional)
Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under  voltage protection, overheat protection and overload protection.
Input and output Input terminal 8 digital input terminals, one of which supports up to 100kHz high-speed pulse input. 2 analog input terminals, one of which only supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input.
Frequency source Digital setting, analog voltage setting, analog current setting, pules setting and serial communication port setting.
Auxiliary frequency source There are ten auxiliary frequency source. It can implement fine tuning of auxiliary frequency and frequency synthesis
Running command source Operation panel / Control terminals / Serial communication port. You can perform switchover between these source in various ways.
Output terminal 1 high-speed pulse output termainal (open-collector) that supports 0-100 kHz square wave signal output. 1 digital  output terminal :that supports 0-20 mA current output or        0-10 V voltage output.
operation on the operation panel LED display It displays the parameters.
Key locking and function selection It can look the keys partially or completely and defind the function range of some keys so as to prevent mis-function
Optional parts Rotating transformer PG card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card